Overview
The T775 electronic remote temperature controllers are the next generation of commercial and agricultural controls capable of remote sensing of temperature and providing switched and/or proportional outputs to various types of loads.
Features
- Save time on installations with the easy-to-use graphical Interface, large display, and the intuitive programming.
- Use the time clock scheduler or digital input to control the setback and disable output options to help save energy.
- Protect equipment from freezing or overheating on models with the modulating high or low limit control option.
- Get pinpoint control on modulating outputs by setting the integral and derivative times (PI or PID).
- Configure models with reset in a few easy steps.
- Control floating actuators with floating outputs on select models.
- Eliminate the need for a separate time delay device and protect equipment with the minimum off time option.
- Sensor 50021579-001 included with non-NEMA 4X models.
- Sensor T775-SENS-WR included with NEMA-4X models.
Product Specifications
- Application
- On/off or analog controller for applications where electronic accuracy and remote sensing of temperature is required.
- Dimensions (in.)
- 8 5/32 in. high x 4 13/32 in. wide x 2 15/16 in. deep
- Dimensions (mm)
- 207.1 mm high x 112.1 mm wide x 74 mm deep
- Item Type
- Product
- Frequency
- 50 Hz; 60 Hz
- Approvals, Underwriters Laboratories Inc.
- Approved
- Voltage
- 24 Vac or 120/240 Vac
- Setpoint Temperature Range (C)
- -40 C to 120 C
- Setpoint Temperature Range (F)
- -40 F to 248 F
- Operating Temperature Range (F)
- Ambient-- -40 F to 140 F @ 60 Hz; -40 F to 125 F @ 50 Hz
- Operating Temperature Range (C)
- Ambient-- -40 C to 52 C @ 50 Hz; -40 C to 60 C @ 60 Hz
- Approvals, CE
- Approved
- Approvals, Canadian Underwriters Laboratories Inc.
- Approved
- Approvals, Others
- IP65: Approved
- Analog Output
- 2,Electronic Series 90; 4-20 mA; 0-10 Vdc; 2-10 Vdc
- Relay Outputs
- 4 SPDT
- Relay Contact Ratings
- 24 Vac-- 10.0A resistive; 120 Vac-- 1/2 hp; 9.8 AFL, 58.8 ALR, 125 VA Pilot Duty; 240 Vac-- 1/2 hp; 4.9 AFL, 29.4 ALR, 125 VA Pilot Duty
- Sensor Inputs
- 2
- Sensor Element
- 1097 ohms PTC at 77 F (25 C)
- Sensors Included
- 50021579-001 (1)
- Maximum distance to sensor (ft)
- Up to 1,000 ft
- Maximum distance to sensor (m)
- up to 304 m
- Bulb Size (in.)
- 1/4 in. diameter x 2 in. long
- Bulb Size (mm)
- 6.35 mm diameter x 50.8 mm
- Accuracy (F)
- ±1 F at 77 F
- Accuracy (C)
- ±1 C at 25 C
- Throttling Range (F)
- 1 F to 150 F
- Throttling Range (C)
- 0.5 C to 66 C
- Differential Temperature (F)
- 1 F to 150 F
- Differential Temperature (C)
- 0.5 C to 66 C
- Replaces
- T775E1114; T775F1022; T775F1055; T775F1089
- High/Low Mod Limit
- Yes
- Approvals, C-Tick
- Approved