Overview
The T775 electronic remote temperature controllers are the next generation of commercial and agricultural controls capable of remote sensing of temperature and providing switched and/or proportional outputs to various types of loads.
Features
- Save time on installations with the easy-to-use graphical Interface, large display, and the intuitive programming.
- Use the time clock scheduler or digital input to control the setback and disable output options to help save energy.
- Protect equipment from freezing or overheating on models with the modulating high or low limit control option.
- Get pinpoint control on modulating outputs by setting the integral and derivative times (PI or PID).
- Configure models with reset in a few easy steps.
- Control floating actuators with floating outputs on select models.
- Eliminate the need for a separate time delay device and protect equipment with the minimum off time option.
- Sensor 50021579-001 included with non-NEMA 4X models.
- Sensor T775-SENS-WR included with NEMA-4X models.
Product Specifications
- Application
- On/off or analog controller for applications where electronic accuracy and remote sensing of temperature is required.
- Dimensions (in.)
- 8 5/32 in. high x 4 13/32 in. wide x 2 15/16 in. deep
- Dimensions (mm)
- 207.1 mm high x 112.1 mm wide x 74 mm deep
- Item Type
- Product
- Frequency
- 50 Hz; 60 Hz
- Approvals, Underwriters Laboratories Inc.
- Approved
- Voltage
- 24 Vac or 120/240 Vac
- Setpoint Temperature Range (C)
- -40 C to 120 C
- Setpoint Temperature Range (F)
- -40 F to 248 F
- Operating Temperature Range (F)
- Ambient-- -40 F to 140 F @ 60 Hz; -40 F to 125 F @ 50 Hz
- Operating Temperature Range (C)
- Ambient-- -40 C to 52 C @ 50 Hz; -40 C to 60 C @ 60 Hz
- Approvals, CE
- Approved
- Approvals, Canadian Underwriters Laboratories Inc.
- Approved
- Relay Outputs
- 2 SPDT
- Relay Contact Ratings
- 24 Vac-- 10.0A resistive; 120 Vac-- 1/2 hp; 9.8 AFL, 58.8 ALR, 125 VA Pilot Duty; 240 Vac-- 1/2 hp; 4.9 AFL, 29.4 ALR, 125 VA Pilot Duty
- Sensor Inputs
- 2
- Sensor Element
- 1097 ohms PTC at 77 F (25 C)
- Sensors Included
- 50021579-001 (1)
- Maximum distance to sensor (ft)
- Up to 1,000 ft
- Maximum distance to sensor (m)
- up to 304 m
- Bulb Size (in.)
- 1/4 in. diameter x 2 in. long
- Bulb Size (mm)
- 6.35 mm diameter x 50.8 mm
- Accuracy (F)
- ±1 F at 77 F
- Accuracy (C)
- ±1 C at 25 C
- Throttling Range (F)
- 1 F to 150 F
- Throttling Range (C)
- 0.5 C to 66 C
- Differential Temperature (F)
- 1 F to 150 F
- Differential Temperature (C)
- 0.5 C to 66 C
- Replaces
- T775A1019; T775B1000
- Approvals, C-Tick
- Approved
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.