Privacy Statement
Skip Ribbon Commands
Skip to main content
SharePoint
  • Product Info
  • Literature

Overview

High temperature oxygen sensors determine oxygen concentration in air or inert gas mixtures and transmit values via a 4-20mA output signal. Available in 3 probe lengths and 2 02 partial pressure ranges, from 0.1 vol% 02 to 25 vol%02, or 100 vol%02.

Features

  • No moving parts.
  • Low power consumption.
  • No need for temperature stabilization.
  • Functional testing and calibration in ambient air.
  • Long life.
  • 4-20mA output.
  • 24Vdc supply voltage.

Product Specifications

Application
Oxygen Sensor
Dimensions (in.)
1 5/8 in. wide x 2.4h x 27 13/16 in. deep
Dimensions (mm)
42 mm wide x 60 mm high x 706 mm deep
Temperature Range (F)
-148 F to 752 F at probe tip
Temperature Range (C)
-100 C to 400 C at probe tip
Used With
99-4218-14-07|ABC900A,B|SS-810-1-12BT
Voltage
24 Vdc
Approvals, CE
CE
Enclosure Rating
NEMA IP65
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.