Skip Ribbon Commands
Skip to main content
SharePoint

Temperature Sensors

Honeywell's temperature sensors offer accurate performance and reliability and feature solid-state components and are impervious to dust or dirt. Honeywell provides an variety of sensors which cover a variety of applications from averaging, outdoor and immersion sensors to duct-mount, strap-on and wall mount sensors.

TR20 Series Wireless Sensors

TR20 Series Wireless Sensors

The WRECVR receiver and TR21-WS, TR23-WS, TR21-WK, and TR23-WK sensors are a family of wireless wall modules and receivers. All models report space temperature; TR23 models come with setpoint adjustment and override.

Wireless Sensors

Wireless Sensors

TR21-WS and TR23-WS sensors are a family of wireless wall modules. All models report space temperature; TR23 models come with setpoint adjustment and override.

Wireless Receivers

Wireless Receivers

The WRECVR receiver and TR21-WS, TR23-WS, TR21-WK, and TR23-WK sensors are a family of wireless wall modules and receivers.

Wireless Sensor and Receiver Kits

Wireless Sensor and Receiver Kits

The WRECVR receiver and TR21-WS, TR23-WS, TR21-WK, and TR23-WK sensors are a family of wireless wall modules and receivers. All models report space temperature; TR23 models come with setpoint adjustment and override.

Zio

Zio

TR70 and TR71 are 2-wire, non-polarity sensitive, Sylk™ bus communicating wall modules for Spyder™ programmable controllers. All have a space-temperature sensor, network bus jack, and an LCD with three soft keys and two Up/Down adjustment keys.

TR20 Series

TR20 Series

The TR21, TR22, TR23, and TR24 are a family of direct wired wall modules for use with Honeywell Excel 600, 500, 100, and 80 controllers; Excel 10 W7750, W7751A, W7752, and W7753 controllers; W7761 Controller; and Spyder Unitary Controllers.

T7560

T7560

Electronic wall modules with LCD for use with XL10 controllers.

T7770

T7770

20 K ohm NTC non-linear Temperature Wall Module

C7041

C7041

The C7041 Electronic Temperature Sensors are 20K ohm NTC sensors designed to be used with electronic controllers in domestic or commercial heating and cooling systems.

C7770

C7770

Direct wired temperature sensor used to sense discharge or return air temperature in a duct controlled by an Excel 10 Series 2000 Controller.

C7772

C7772

C7772 Temperature Sensors are designed for the Excel 5000 family and other Honeywell controllers. They provide a resistive output signal and are well suited for low profile wall mounted applications.

T775 Series 2000 Sensors

T775 Series 2000 Sensors

A family of general use, simple to use, broadly featured electronic temperature and universal controllers for use in HVAC, agricultural, and industrial applications.

C7021

C7021

10K ohm NTC Temperature Sensor

C7031

C7031

Electronic temperature sensors used with DDC Systems.

C7043

C7043

Temperature sensors are electronic sensors for use with chiller controls.

C7046

C7046

Air Temperature Sensors function as primary and/or secondary sensors in electronic control systems.

C7068

C7068

Temperature sensor used in the CXCLL-IRC system for installation in air terminal units giving the input signal to the unit module, vav-module or the control output module.

C7100

C7100

Averaging Duct Temperature Sensors are used to sense temperature in discharge duct.

C7130

C7130

The C7130A,B Wall-Mount Air Temperature Sensors provide the input required by the R7380J,L, W7100, W7600, W7620, and Excel 500 Control Systems to sense air temperature in indoor spaces.

C7170

C7170

Primary electronic temperature sensor for the R7380J,L, W7100 and W7505 load inputs for immersion, strap-on and duct mounting.

C7173

C7173

Platinum film temperature sensor monitors & controls temperature with an electronic control. Element is soldered to a cable and inserted in a copper capsule. Unit may be surface mounted or inserted in a well assembly and located in a remote area.

KTF20

KTF20

Boiler Temperature Sensor NTC

L7022

L7022

The L7022A Electronic Averaging Sensor is used in commercial air conditioning systems, to provide accurate measurement and control temperature. May also measure concrete slab temperature, or be used to control dew point in an air washer.

L7025

L7025

Moisture proof temperature sensitive resistance element intended for use in conjunction with a bridge and an electronic amplifier.

L7087

L7087

Temperature sensitive resistance element for use in commercial air conditioning control system. Used in conjunction with bridge circuit, electronic amplifier and relay.

L7092

L7092

Temperature sensor that converts temperature to period.

L7093

L7093

Temperature sensor that converts resistance to period for return air applications.

L7095

L7095

Low temperature chilled water sensor that converts temperature to period.

T7005

T7005

Platinum (3000 Ohm RTD) Space Sensor, monitors temperatures in building management control applications, including Direct Digital Control Systems. Used with Excel 5000 Controllers, DELTA 540 and 541 Data gathering panels, DeltaNet R7044 Excel Plus.

T7006

T7006

Platinum (3000 Ohm RTD) Duct Sensor, monitors temperatures in building management control applications, including Direct Digital Control Systems. Used with Excel 5000 Controllers, DELTA 540 and 541 Data gathering panels, DeltaNet R7044 Excel Plus C.

T7007

T7007

Platinum (3000 Ohm RTD) Remote Bulb Sensor, monitors temperatures in building management control applications, including Direct Digital Control Systems. Used with Excel 5000 Controllers, DELTA 540 and 541 Data gathering panels, DeltaNet R7044 Excel.

T7008

T7008

Platinum (3000 Ohm RTD) Immersion Sensor, monitors temperatures in building management control applications, including Direct Digital Control Systems. Used with Excel 5000 Controllers, DELTA 540 and 541 Data gathering panels, DeltaNet R7044 Excel P.

T7022

T7022

The T7022 Remote Temperature Sensor is a non-adjustable thermistor sensor. Its primary use is with the T7300 Programmable Commercial Thermostat (only in return air) to control heating or cooling equipment.

T7047

T7047

The T7047 Electronic Thermostats, Remote Space Sensors are used with T7300 thermostats and W973 controller to provide modulating space temperature control.

T7147

T7147

For use with T7300/Q7300 Thermostat system to provide space temperature sensing, and switch initiation and indication of overrides from remote location.

T7771

T7771

Temperature Sensor for use with T7350

T7335

T7335

A NTC temperature sensor designed to work in conjunction with the W9335A modureg driver. Sensor is well immersion type.

T7515

T7515

3000 ohm Temperature Space Sensor.

C7750

C7750

The C7750A temperature sensor senses discharge or return air in a duct. It consists of a temperature sensitive 20K ohm thermistor that is connected on a circuit board to two linearizing resistors in series-parallel configuration.

TR29

TR29

The TR29 is a wall mount enclosure only and can be used to wall-mount any 1/4-in.or 3/8-in. diameter probe sensor.

T7412

T7412

Room Temperature Sensor for wall mounting in a decorative housing. Used in Excel-IRC system for room air temperature measurement as input to the control output module, VAV control module, or the unit module.

T7750

T7750

T7750 Wall Modules provide the following additional combination of options to the customer: analog setpoint input and for models used with Excel 10 Controllers, override (bypass) digital input contact, LED status indicator and network access jack.

TB-WALL

TB-WALL

Honeywell 10K ohm NTC Type II remote wall sensors are for use with the TB7200, TB7300, and TB7600 Series communicating thermostats and other devices requiring a 10K ohm NTC Type II sensor. These robust sensors provide accurate and stable temperature readings using a 10K ohm NTC thermistor element.

C7776

C7776

The C7776 Air Temperature Sensors are direct wired temperature sensors that are used to sense discharge or return air in a duct.

C7778

C7778

he C7778 Air Temperature Sensors are direct wired temperature sensors that are used to sense discharge or return air in a duct.

Zio Lite

Zio Lite

The TR40 and TR42 are 2-wire, non-polarity sensitive, Sylk bus communicating wall modules, which communicate with Spyder® and some ComfortPoint™ programmable controllers.

T7506

T7506

T7506 electronic wall-mounted Balco sensors sense temperature in electronic HVAC systems. They are used with MicroniK, Excel, and Excel Plus Controllers.

Zio Plus

Zio Plus

The TR75 and TR75-H are 2-wire, non-polarity sensitive, Sylk™ bus communicating wall modules for use with Spyder™ programmable controllers which are compatible with the Sylk bus. All models have a space-temperature sensor, network bus jack, and an LCD with three soft keys and two Up/Down adjustment keys. Like the TR71, but includes access to controller schedule and has more memory for additional parameters