Privacy Statement
Skip Ribbon Commands
Skip to main content
SharePoint

Switches

Valve/Modulating Actuator Combination

Valve/Modulating Actuator Combination

VC7936 fail safe modulating control valves and actuator assemblies provide proportional control of hot or chilled water in commercial HVAC applications, such as unit ventilators and re-heat coils.

Valve/Floating Actuator Combinations

Valve/Floating Actuator Combinations

VC6936 fail safe floating control valves and actuator assemblies provide proportional control of hot or chilled water in commercial HVAC applications, such as unit ventilators and re-heat coils.

ML4702

ML4702

Honeywell ML4115 direct coupled actuators (DCA) for damper control accepts an on/off signal from a single-pole, single-throw (SPST) controller. Operates reliably in smoke control systems requiring UL555S ratings up to 350F.

Direct Coupled Valve Actuator Accessories and Parts

Direct Coupled Valve Actuator Accessories and Parts

Auxiliary Potentiometers, switches, adapter kits and more parts and accessories for direct coupled valve actuators.

VC Series Two-position Actuators

VC Series Two-position Actuators

Control central heating and/or cooling systems, fan coil systems, radiators and convectors. Depending on the model selected, the actuator can be controlled by either a low or line voltage SPST or SPDT controller such as a room thermostat.

VC Series Floating/Modulating Actuators

VC Series Floating/Modulating Actuators

Control central heating and cooling, fan coil systems, radiators and convectors. Depending on the model, the actuator can be controlled by a low voltage SPST or SPDT switch, pulse-width modulated 24 Vac signal, or floating input, modulating controller.

VC Series Fail Safe Floating/Modulating Actuators

VC Series Fail Safe Floating/Modulating Actuators

Control central heating and/or cooling systems, fan coil systems, radiators and convectors. Depending on the model selected, the actuator can be controlled by either a low or line voltage SPST or SPDT or floating or modulating controller.

MVN

MVN

MVN rotary valve actuators for use with control ball valves and pressure independent control valves. Reduce labor costs associated with mechanical and electrical installation, commissioning and service. Innovative design makes assembly easy, saving you time and money.

M6410/M7410

M6410/M7410

Cartridge globe valve actuators are small electric actuators for individual room control that provide floating or modulating control of V5852, V5862 two-way or V5853, V5863 three-way valves.

M6435/M7435

M6435/M7435

Cartridge globe valve spring return actuators are small electric actuators for individual room control that provide floating or modulating control of V5852, V5862 two-way or V5853, V5863 three-way valves.

Fan Coil Valve Actuators

Fan Coil Valve Actuators

Humidity resistant fan coil valve actuators are used in conjunction with VU52, VU53 and VU54 valves for controlling the flow of hot or chilled water in commercial HVAC equipment such as fan coil units, terminal reheat coils and convectors.

ML6420/ML7420

ML6420/ML7420

Non-spring return electric linear valve actuators have floating or modulating control and operate standard Honeywell valves in heating, ventilating, and air conditioning (HVAC) applications.

ML6421/ML7421

ML6421/ML7421

Direct coupled globe valve actuators provide floating or modulating control of chilled water, hot water or steam, and mount directly on VGF series, V5011 and V5013 valves. These non-spring return high force actuators will operate 1-1/2 to 6 inch valves.

ML6425/ML7425

ML6425/ML7425

Direct coupled globe valve actuators provide floating and modulating control of chilled water, hot water and steam, and mount directly on VGF series, V5011 and V5013 globe valves. These spring return actuators will operate 1/2 to 3 inch valves.

ML6984/ML7984

ML6984/ML7984

Self-contained, self-adjusting, motorized linkage that mounts directly onto V5011 two-way or V5013 three-way valves and provides up to 25 mm (1") of linear stem travel.

M6061/M7061

M6061/M7061

Rotary valve actuator for butterfly valves designed to provide floating or modulating control in commercial HVAC applications.