VCZN
Three-way Cartridge Cage Valves are intended for hydronic applications in a normal indoor environment to control the flow of hot water or chilled water glycol solution to 60% concentration. These valves are designed for zone control of heating/cooling systems, or to control individual fan coil, baseboard radiator or convector applications. Depending on the model selected they can be controlled by SPST or SPDT two position controller, tristate (floating), or modulating proportional controller. For best control, outdoor temperature compensation of supply water temperature is recommended. For trouble-free operation of the product, good installation practice must include initial system flushing, chemical water treatment, and the use of a 50 micron (or finer) system side stream filter(s). Remove all filters before flushing.
Compare Select and Compare the Product Models below.  Limited to five.  Some groupings may not be comparable.
  
VCZNB6100
3-way 1/2 in. fNPTconnection VC valve assembly for hydronic with 3.7 Cv and linear flow
View Product Information
VCZNB6131
3-way 1/2 in. fNPTconnection VC valve assembly for hydronic with 3.7 Cv and linear flow
View Product Information
VCZNB7100
3-way 1/2" fNPT 3.8Cv, linear flow, for use with non-fail safe proportional actuators
View Product Information
VCZNB7400
3-way 1/2" fNPT 2.7Cv, equal percentage flow, for use with non-fail safe proportional actuators
View Product Information
VCZNB7500
3-way 1/2" fNPT 0.7Cv, equal percentage flow, for use with non-fail safe proportional actuators
View Product Information
VCZNB7600
3-way 1/2" fNPT 1.3Cv, equal percentage flow, for use with non-fail safe proportional actuators
View Product Information
VCZND6100
3-way 1 1/4 in. fNPTconnection VC valve assembly for hydronic with 9 Cv and linear flow
View Product Information
VCZND6131
3-way 1 1/4 in. fNPTconnection VC valve assembly for hydronic with 9 Cv and linear flow
View Product Information
VCZND7100
3-way 1-1/4" fNPT 8.3Cv, linear flow, for use with non-fail safe proportional actuators
View Product Information
VCZNE6100
3-way 1 1/4 in. sweat connection VC valve assembly for hydronic with 9 Cv and linear flow
View Product Information
VCZNE7100
3-way 1-1/4" fNPT 8.3Cv, linear flow, for use with non-fail safe proportional actuators
View Product Information