VCZM
Three-way Cartridge Cage Valves are intended for hydronic applications in a normal indoor environment to control the flow of hot water or chilled water glycol solution to 60% concentration. These valves are designed for zone control of heating/cooling systems, or to control individual fan coil, baseboard radiator or convector applications. Depending on the model selected they can be controlled by SPST or SPDT two position controller, tristate (floating), or modulating proportional controller. For best control, outdoor temperature compensation of supply water temperature is recommended. For trouble-free operation of the product, good installation practice must include initial system flushing, chemical water treatment, and the use of a 50 micron (or finer) system side stream filter(s). Remove all filters before flushing.
Compare Select and Compare the Product Models below.  Limited to five.  Some groupings may not be comparable.
  
VCZMA6100
3-way 1/2 in. sweat connection VC valve assembly for hydronic with 3.8 Cv and linear flow
View Product Information
VCZMA7100
3-way 1/2" sweat 3.8Cv, linear flow, for use with non-fail safe proportional actuators
View Product Information
VCZMA7400
3-way 1/2" sweat 2.7Cv, equal percentage flow, for use with non-fail safe proportional actuators
View Product Information
VCZMA7500
3-way 1/2" sweat 0.7Cv, equal percentage flow, for use with non-fail safe proportional actuators
View Product Information
VCZMA7600
3-way 1/2" sweat 1.3Cv, equal percentage flow, for use with non-fail safe proportional actuators
View Product Information
VCZMA7800
3-way 1/2" sweat 2.2Cv, equal percentage flow, for use with non-fail safe proportional actuators
View Product Information
VCZMC6100
3-way 1/2 in. flare connection VC valve assembly for hydronic with 3.8 Cv and linear flow
View Product Information
VCZMD6100
3-way 1/2 in. inverted flare connection VC valve assembly for hydronic with 3.2 Cv and linear flow
View Product Information
VCZMK6100
3-way 3/4 in. fNPTconnection VC valve assembly for hydronic with 6.6 Cv and linear flow
View Product Information
VCZMK6131
3-way 3/4 in. fNPTconnection VC valve assembly for hydronic with 6.6 Cv and linear flow
View Product Information
VCZMK7100
3-way 3/4 in. fNPTconnection VC valve assembly for hydronic with 6.6 Cv and linear flow
View Product Information
VCZMK7400
3-way 3/4 in. fNPTconnection VC valve assembly for hydronic with 6.6 Cv and equal percentage flow
View Product Information
VCZMK7800
3-way 3/4 in. fNPTconnection VC valve assembly
View Product Information
VCZML6100
3-way 3/4 in. sweat connection VC valve assembly for hydronic with 5.9 Cv and linear flow
View Product Information
VCZML7100
3-way 3/4 in. sweat connection VC valve assembly for hydronic with 5.9 Cv and linear flow
View Product Information
VCZML7400
3-way 3/4 in. fNPTconnection VC valve assembly for hydronic with 6.6 Cv and equal percentage flow
View Product Information
VCZML7800
3-way 3/4 in. fNPTconnection VC valve assembly
View Product Information
VCZMR6100
3-way 1 in. fNPTconnection VC valve assembly for hydronic with 8.6 Cv and linear flow
View Product Information
VCZMR6131
3-way 1 in. fNPTconnection VC valve assembly for hydronic with 9 Cv and linear flow
View Product Information
VCZMR7100
3-way 1 in. fNPTconnection VC valve assembly for hydronic with 7.4 Cv and linear flow
View Product Information
VCZMS6100
3-way 1 in. sweat connection VC valve assembly for hydronic with 9 Cv and linear flow
View Product Information
VCZMS7100
3-way 1 in. sweat connection VC valve assembly for hydronic with 8.3 Cv and linear flow
View Product Information