VCZA
Two-way Cartridge Cage Valves are intended for hydronic applications in a normal indoor environment to control the flow of hot water or chilled water glycol solution to 60% concentration. These valves are designed for zone control of heating/cooling systems, or to control individual fan coil, baseboard radiator or convector applications. Depending on the model selected they can be controlled by SPST or SPDT two position controller, tristate (floating), or modulating proportional controller. For best control, outdoor temperature compensation of supply water temperature is recommended. For trouble-free operation of the product, good installation practice must include initial system flushing, chemical water treatment, and the use of a 50 micron (or finer) system side stream filter(s). Remove all filters before flushing.
Compare Select and Compare the Product Models below.  Limited to five.  Some groupings may not be comparable.
  
VCZAA1100
2-way 1/2 in. sweat connection VC valve assembly for hydronic with 3.5 Cv and linear flow
View Product Information
VCZAA1400
2-way 1/2 in. sweat connection VC valve assembly for hydronic with 2.9 Cv and equal percentage flow
View Product Information
VCZAA1500
2-way 1/2 in. sweat connection VC valve assembly for hydronic with 0.7 Cv and equal percentage flow
View Product Information
VCZAA1600
2-way 1/2 in. sweat connection VC valve assembly for hydronic with 1.3 Cv and equal percentage flow
View Product Information
VCZAA3100
2-way 1/2 in. sweat connection VC valve assembly for hydronic with 3.5 Cv and linear flow
View Product Information
VCZAA3400
2-way 1/2 in. sweat connection VC valve assembly for hydronic with 2.3 Cv and equal percentage flow
View Product Information
VCZAA3500
2-way 1/2 in. sweat connection VC valve assembly for hydronic with 0.7 Cv and equal percentage flow
View Product Information
VCZAA3600
2-way 1/2 in. sweat connection VC valve assembly for hydronic with 1.3 Cv and equal percentage flow
View Product Information
VCZAA3800
2-way 1/2 in. sweat connection VC valve assembly for hydronic with 1.9 Cv and equal percentage flow
View Product Information
VCZAD1000
2-way 1/2 in. flare connection VC valve assembly for hydronic with 3.4 Cv and quick open flow
View Product Information
VCZAD1100
2-way 1/2 in. flare connection VC valve assembly for hydronic with 3.1 Cv and linear flow
View Product Information
VCZAE1100
2-way 1/2 in. inverted flare connection VC valve assembly for hydronic with 3.2 Cv and linear flow
View Product Information
VCZAL1100
2-way 3/4 in. fNPTconnection VC valve assembly for hydronic with 4.7 Cv and linear flow
View Product Information
VCZAL1131
2-way 3/4 in. fNPTconnection VC valve assembly for hydronic with 4.7 Cv and linear flow
View Product Information
VCZAL1600
2-way 3/4 in. fNPTconnection VC valve assembly for hydronic with 1.3 Cv and equal percentage flow
View Product Information
VCZAL3100
2-way 3/4 in. fNPT connection VC valve assembly for hydronic with 3.5 Cv and linear flow
View Product Information
VCZAL3400
2-way 3/4 in. fNPT connection VC valve assembly for hydronic with 2.9 Cv and equal percentage flow
View Product Information
VCZAL3800
2-way 3/4 in. fNPT connection VC valve assembly for hydronic with 1.9 Cv and equal percentage flow
View Product Information
VCZAM1100
2-way 3/4 in. sweat connection VC valve assembly for hydronic with 4.6 Cv and linear flow
View Product Information
VCZAM1400
2-way 3/4 in. sweat connection VC valve assembly for hydronic with 3.9 Cv and equal percentage flow
View Product Information
VCZAM3100
2-way 3/4 in. sweat connection VC valve assembly for hydronic with 3.5 Cv and linear flow
View Product Information
VCZAM3400
2-way 3/4 in. sweat connection VC valve assembly for hydronic with 2.9 Cv and equal percentage flow
View Product Information
VCZAM3800
2-way 3/4 in. sweat connection VC valve assembly for hydronic with 1.9 Cv and equal percentage flow
View Product Information
VCZAR1100
2-way 1 in. fNPTconnection VC valve assembly for hydronic with 6.6 Cv and linear flow
View Product Information
VCZAR1131
2-way 1 in. fNPTconnection VC valve assembly for hydronic with 6.6 Cv and linear flow
View Product Information
VCZAR1400
2-way 1 in. fNPTconnection VC valve assembly for hydronic with 4.2 Cv and equal percentage flow
View Product Information
VCZAR3100
2-way 1 in. fNPT connection VC valve assembly for hydronic with 3.5 Cv and linear flow
View Product Information
VCZAR3400
2-way 1 in. fNPT connection VC valve assembly for hydronic with 2.9 Cv and equal percentage flow
View Product Information
VCZAS1100
2-way 1 in. sweat connection VC valve assembly for hydronic with 6.6 Cv and linear flow
View Product Information
VCZAS1400
2-way 1 in. sweat connection VC valve assembly for hydronic with 4.2 Cv and equal percentage flow
View Product Information
VCZAS3100
2-way 1 in. sweat connection VC valve assembly for hydronic with 3.5 Cv and linear flow
View Product Information
VCZAS3400
2-way 1 in. sweat connection VC valve assembly for hydronic with 2.9 Cv and equal percentage flow
View Product Information
Compare Select and Compare the Product Models above.  Limited to five.  Some groupings may not be comparable.