Environmental & Combustion Controls
Fan Coil/Zone Thermostats
Fan Coil Thermostats provide heating and cooling control of unitary equipment.

Compare Select and Compare the Product Models below.  Limited to five.  Some groupings may not be comparable.
  
T4039
Fan Coil Thermostats, line voltage, manual or automatic changeover
T6069
T6069 thermostats control line voltage valves and/or blower motors on fan coil units in manual changeover heating/cooling systems.
T6169
Fan Coil Thermostat. Control line voltage valves and/or blower motors on fan coil units in manual or automatic changeover heating and cooling systems. The T6169 thermostats feature single "System" and "Fan Speed" switch.
T6381
Electronic Fan Coil Thermostats provide precise control of line-voltage fan-forced, heating ventilating, and air conditioning equipment. 2-pipe and 4-pipe models available.
T6383
Electronic Fan Coil Thermostats provide precise control of line-voltage fan-forced, heating ventilating, and air conditioning equipment. 2-pipe and 4-pipe models available.
T6574
Digital Fan-Coil Thermostat
T6575
Digital Fan-Coil Thermostat
T8574
Digital Fan-Coil Thermostat
T8575
Digital Fan-Coil Thermostat
SuitePRO
Digital Fan-Coil thermostats for residential and commercial applications
Fan Coil/Zone Thermostats Accessories
Compare Select and Compare the Product Models above.  Limited to five.  Some groupings may not be comparable.
Search By Specification
Search Clear Search Criteria
Application
2 or 4 pipe fan coil, Heat/Cool manual/auto changeover, 3-speed fan, 120 - 240 Vac2 or 4 pipe fan coil, Heat/Cool manual/auto changeover, 3-speed fan, 24 Vac
2 pipe fan coil, cooling only, constant fan2 pipe fan coil, cooling only, constant fan, 240 Vac
2 pipe fan coil, heat or cool , 24Vac2 pipe fan coil, heat or cool , constant or cycled fan, 24Vac
2 pipe fan coil, heat or cool, no fan switching, 240 Vac2 pipe fan coil, heat or cool, no fan switching, 240 Vac, with remote sensor
2 pipe fan coil, Heat/Cool manual/auto changeover, 3-speed fan, 120 - 240 Vac2 pipe fan coil, manual heat-cool changeover, constant fan
2 pipe fan coil, manual heat-cool changeover, constant fan, 240 Vac2 pipe fan coil, manual heat-cool changeover, constant fan, electric heater, 240 Vac
2 pipe fan coil, manual heat-cool changeover, constant fan, electric heater, 240 Vac, with remote sensor2 pipe fan coil, manual heat-cool changeover, constant or cycled fan
2 pipe fan coil, manual heat-cool changeover, cycled fan, 240 Vac2 pipe fan coil, manual or auto changeover
2 pipe fan coil, seasonal auto changeover, constant fan, 120 Vac2 pipe fan coil, seasonal auto changeover, constant fan, 240 Vac
2 pipe fan coil, seasonal auto changeover, constant or cycled fan2 pipe fan coil, seasonal auto changeover, constant or cycled fan, 120 Vac
2 pipe fan coil, seasonal auto changeover, constant or cycled fan, 240 Vac2 pipe fan coil, seasonal auto changeover, constant or cycled fan, 240 Vac, with remote sensor
2 pipe fan coil, seasonal auto changeover, constant or cycled fan, 277 Vac2 pipe fan coil, seasonal auto changeover, cycled fan, 120 Vac
2 pipe fan coil, seasonal auto changeover, cycled fan, 240 Vac2 pipe fan coil, seasonal heat-cool changeover, constant fan, 24 Vac
2 pipe fan coil, seasonal heat-cool changeover, constant or cycled fan, 24 Vac2 pipe fan coil, seasonal heat-cool changeover, cycled fan, 24 Vac
2-pipe2-pipe Fan speed control
2-pipe or 4-pipe4 pipe fan coil, automatic heat-cool changeover
4 pipe fan coil, automatic heat-cool changeover, constant fan, 120 Vac4 pipe fan coil, automatic heat-cool changeover, constant fan, 24 Vac
4 pipe fan coil, automatic heat-cool changeover, constant fan, 277 Vac4 pipe fan coil, automatic heat-cool changeover, constant or cycled fan, 120 Vac
4 pipe fan coil, automatic heat-cool changeover, constant or cycled fan, 24 Vac4 pipe fan coil, automatic heat-cool changeover, constant or cycled fan, 277 Vac
4 pipe fan coil, manual heat-cool changeover4 pipe fan coil, manual heat-cool changeover, constant fan
4 pipe fan coil, manual heat-cool changeover, constant fan, 120 Vac4 pipe fan coil, manual heat-cool changeover, constant fan, 24 Vac
4 pipe fan coil, manual heat-cool changeover, constant fan, 240 Vac4 pipe fan coil, manual heat-cool changeover, constant fan, 277 Vac
4 pipe fan coil, manual heat-cool changeover, cycled fan4 pipe fan coil, manual heat-cool changeover, cycled fan, 120 Vac
4 pipe fan coil, manual heat-cool changeover, cycled fan, 24 Vac4 pipe fan coil, manual heat-cool changeover, cycled fan, 240 Vac
4 pipe fan coil, manual heat-cool changeover, no fan switching4-pipe Heat Cool
AccessoryFan coil, cooling only
Changeover
Auto C/O with external aquastatAutomatic
Automatic optional with external Aquastat® controllerAutomatic, by room temperature
InternationalManual
Manual/AutoRemote changeover switch is required to separate circuits in manual changeover heating-cooling models.
Seasonal AutoSeasonal Auto C/O with external aquastat
Seasonal Auto with External Aquastat® Controller
Switch Positions (System)
Auto-OffAUTO-ON
HEAT-COOLHEAT-OFF-COOL
HI-OFF-LOHI-OFF-MED-LO
HI-OFF-MED-LO (constant)HI-OFF-MED-LO (Cycled)
No SwitchOFF-HEAT-COOL-AUTO
OFF-HI-LO, Off breaks cooling and fan circuitsOFF-HI-LOW
ON-AUTO-OFFON-OFF
Switch Positions (Fan)
1-speed3-speed
HI-LOHI-MED-LO
HI-MED-LO (constant)HI-MED-LO (continuous)
HI-MED-LO (cycled)HI-MED-LO (on-auto)
HI-MED-LO-OFF-ONHI-MED-LOW (constant fan)
HI-MED-LOW-AUTO-OFFHI-OFF-MED-LO
HI-OFF-MED-LO (constant)HI-OFF-MED-LO (cycled)
Color
GoldIvory/Gold
Premier White®Tan
Whitewhite with green ring
Setting Temperature Range (F)
44 F to 86 F50 F to 90 F
55 F to 90 F55 F to 95 F, marked COOL-WARM
60 F to 90 F
Setting Temperature Range (C)
10 C to 30 C10 C to 32 C
13 C to 35 C13 C to 35 C, marked COOL-WARM
13 to 32 C7 C to 28 C