Environmental & Combustion Controls
Communicating Programmable Commercial Thermostats
The T7350 Communicating commercial programmable thermostat is the new benchmark for energy savings, consistent comfort and the convenience of both dial up and web based operations.

Compare Select and Compare the Product Models below.  Limited to five.  Some groupings may not be comparable.
  
T7350H
T7350 LonWorks(R) Communicating Thermostat
Y7355
Compare Select and Compare the Product Models above.  Limited to five.  Some groupings may not be comparable.
Search By Specification
Search Clear Search Criteria
Application
Commissioning softwareConventional and Heat Pump systems
Conventional systemsHeat Pump Systems
Modulating Systems
Part
softwaresubbase
thermostat + subbasethermostat and subbase
Stages
2 Heat / 1 Cool2 Mod (4-20mA)/ 2 Relay
3 Heat / 2 Cool3 Heat / 3 Cool
Network Communications
LonWorks BusLonWorks Bus and PDA Serial Port
None
Switch Positions (System)
Determined by the chosen thermostatHEAT-OFF-COOL-AUTO-EM.HEAT
Switch Positions (Fan)
AUTO-ONDetermined by the chosen thermostat
Color
TaupeTrident White
Comments
Does not have O and B terminalsEnergyStar product (Title 24 compliant product), Remote Temp, Outdoor, Discharge Air, Humidity and Occupancy
Has O and B terminalsoutputs to drive an ML7984 approximately 40% on 1rst stage of heat and 100% on second Stage
Remote Temp, Outdoor, Discharge Air, Humidity, EnergyStar ProductRemote Temp, Outdoor, Discharge Air, Humidity, Occupancy
Includes
EB terminals for LonWorks bus connectionQ7300H2002 subbase, T7300F2010 Thermostat, C7046C1000 Sensor
Q7300H2011 Subbase, T7300F2010 Thermostat, C7046C1000 SensorQ7300H2029 Subbase, T7300F2010 Thermostat, C7046C1000 Sensor
Q7300H2037 Subbase, T7300F2010 thermostat, C7046C1000 Sensorsingle or 2 speed fan control; pump interlock relay; damper relay.
T7350H1009, C7041B2005, T7771A1005