View or Download the Brochure
This in-depth technical training focuses on building Core Competency in 3 areas:
- Basic – LON Fundamentals (provided by Echelon Corp.) and WEBs Access Control
- Core – WEBs-AX and Spyder LON & BACnet competencies and XL15C/LCBS migration. Note, Niagara Certification (provded via Tridium or M.O.V Training Services) is required for these courses
- System – Enterprise-level WEBs-AX Supervisor and Multi-Protocol Integration.
Please work with your Authorized Systems Distributor or Honeywell Sales Representative to schedule a course.
The courses listed below will be held at the Honeywell Golden Valley Learning Center in Golden Valley, MN.
SPYDER LON CORE COMPETENCY
The class starts by introducing the student to the Honeywell Spyder series of programmable unitary controllers and advances to job implementation. Topics include specifications, architecture, commissioning, function blocks, simulation, debugging, downloading, LON network variables, proxy points, time schedules, applications, macros and sample programs.
This 2-day, hands-on course includes:
• Training materials
• On-site transportation
• Hotel accommodations
• Breakfast and lunch daily
• Spyder LON Core Certificate
Mandatory Prerequisite: NiagaraAX Certification #HTTP-201
Recommended: WEBs-AX Core Competency #HTTP-202
Honeywell Training Center
Course #: HTTP-203
2012 Course Offerings:
• May 8 - 9
• August 7 - 8
• October 23 - 24
Cost: $1,300 or 65,000 Contractor PRO points
*Includes 3 nights hotel
Click HERE to register.
____________________________________________________________
SPYDER BACnet CORE COMPETENCY
Class topics include controller specifications, BACnet architecture, device addressing, function blocks, simulation, debugging, macros, applications, BACnet objects, proxy points, time schedules, Spyder library, priority array, Zio™ wall module, VAV balancing, Spyder migration, Spyder alarms, and sharing LON and BACnet applications between devices.
This 3-day, hands-on course includes:
• Training materials
• On-site transportation
• Hotel accommodations
• Breakfast and lunch daily
• Spyder BACnet Core Certificate
Mandatory Prerequisite: NiagaraAX Certification #HTTP-201
Recommended: WEBs-AX Core Competency #HTTP-202
Honeywell Training Center
Course #: HTTP-205
2012 Course Offerings:
• April 3 - 5
• June 12 - 14
• September 11 - 13
• November 13 - 15
Cost: $1,900 or 95,000 Contractor PRO Points
*Includes 4 nights hotel
Click HERE to register.
____________________________________________________________
ENTERPRISE LEVEL WEBs-AX SUPERVISOR
Audience: Class is designed for students already NiagaraAX certified and
who have Honeywell WEBs field experience.
Description: This class builds on the WEBs-AX core competency class,
taking a single WEBs Controller System and expanding it into an
Enterprise Level Multiple WEBs Controller System. The class topics
include specifications, architecture, platforms, stations, NiagaraAX
network, station discovery, network user accounts, supervisor proxy
points, supervisor schedules, supervisor alarming, supervisor history
collection, BQL query builder and system reporting.
This 3-day, hands-on course includes:
• Training materials
• On-site transportation
• Hotel accommodations
• Breakfast and lunch daily
• Enterprise Level WEBs-AX Supervisor Certificate
Mandatory Prerequisite: NiagaraAX Certification (HTTP-201)
Recommended: WEBs-AX Core Competency (HTTP-202)
Honeywell Training Center
Course #: HTTP-301
2012 Course Offerings:
• April 17 - 19
• July 10 - 12
Cost: $1,900 or 95,000 Contractor PRO Points
*Includes 4 nights hotel
Click HERE to register.